Equisys technical notes

Technical guidance, explanations and fixes for our products

FIX: Print to fax addressing dialog is not presented in a terminal session running Zetafax 9.1.

Print

ZTN1450

ID: ZTN1450

This Zetafax technical note applies to:

  • Zetafax Version 9.1

Symptom

This patch resolves the symptom of documents not being successfully printed and the user is not presented with the addressing dialog box.

Cause

The print controller fails to determine the correct user area when creating the printed spool file.

Resolution

The update is available via the Zetafax Update Service. To check for updates simply click the “ Check for Updates… ” shortcut under Start/Programs/Zetafax  on the Zetafax server, or by clicking “ Check for Updates… ” in the help menu of the Zetafax Server application.

Alternatively  this issue can be resolved  manually by downloading  the updated print controller  from here.

ftp://www.equisys.com/pub/Zetafax9.1/Updates/ZfPrnctl91updt.exe

Having downloaded and applied the update, the patch needs to be distributed to all machines that have the Zetafax Client currently installed. This  can be done by running the Zetafax Client install from each workstation affected.

Alternatively the client can be rolled out using group policy as documented in ZTN1336 - HOWTO: How to install the Zetafax client using group policy.    

Status

This behaviour was corrected in the above patch.

Last updated: 08 September 2005 (EB/SV/LD)

First Published: 25 April 2005 (BM/SV)

Equisys Logo, Document Management and Expense Management for Business Central
 

Replaced by script