Symptom
Dialogic Trufax full length boards do not start up correctly when Zetafax Server is run, the boards fail to initialise.
Cause
The Trufax full length boards are added as devices using an older version of the Brooktrout SDK. This is not compatible with later versions of Windows Server.
Resolution
In Zetafax Configuration Program, remove the Trufax full length device if it has been added, then re-add the board as a Trufax half length device.
Note that for Windows Server 2012 R2 with Zetafax 2014, the Brooktrout driver version 6.7.0 update must be installed beforehand.
References
ZTN2062 – INFO Changes in Brooktrout driver version 6.7.0 update
Last updated: 15th September 2014 (NT/JV)