FIX: Zetadocs Document Converter fails to convert when Abbyy is enabled
ZTN4427
ID: ZTN4427
This Zetadocs technical note applies to:
- Systems that have Intel Xeon CPUs or similar
- Zetadocs Server version 2.2.107 and earlier.
Symptom
The Zetadocs Server service is able to start, but no documents are converted. This only applies when the Abbyy OCR functionality is enabled. The logs do not show any errors.
Cause
This was caused due to Xeon CPUs not being supported in the version of the Abbyy engine shipped with Zetadocs Server.
Resolution
This fault was corrected in a hotfix, which is available by contacting Equisys Technical Support and quoting the technote number ZTN4427.
Status
This behaviour was corrected in the hotfix detailed above.
Last updated: 13th August 2015 (JC/JV)