FIX: Zetadocs stops processing documents in the batch split and root folders
ZTN4492
This Zetadocs technical note applies to:
- Version 8 of Zetadocs Server or later
Symptom
Documents in the batch split and root folders are not being processed by Zetadocs when the amount of documents in any of the folders was extremely high. Although the Zetadocs Document Converter service continues to run, it requires a manual restart in order to begin processing documents again.
Upon looking in the ZdDocumentConverter log there may be an error message stating:
“BatchScanFolders_Error(): An error has occurred: Too many changes at once in directory”
A similar error may occur when using the root folder.Cause
This is caused by too many events occurring in the folders in a short amount of time, possible causes for this include; a large file being streamed/scanned to the folder, or a large number of files being added to the folders at once.
Resolution
This fault was corrected in a hotfix, which is available by contacting Equisys Technical Support and quoting the technote number ZTN4492.
Status
This behaviour was corrected in the ZTN4492 hotfix detailed above.
Last updated: 30th June 2017 (JL/JV/ZP)
Keywords: Zetadocs NAV Server, Batch Split Folder, Document Converter