FIX: ComponentMoveData error when installing Zetafax Server and Client Version 8.0.1 update
Print
ZTN1300
ID: ZTN1300
This Zetafax technical note applies to:
- Zetafax Server and Client - Version 8.0.1 Update download
Symptom
After running the downloaded Zetafax Server and Client update from the Equisys website, you may receive the following error messages.
Cause
This is caused by the updated package not being able to create the installation files in a temporary location on the system the update is run on.
Resolution
Equisys has provided a version of this update without the update package which normally automates the extraction of the update then runs the appropriate setup program.
This updated download can be found at the following URL:
ftp://www.equisys.com/pub/Zetafax8.0.1/zfupdate_i.exe
After downloading, run the self-extracting zip file extract the files to the default location (as below),
Browse to the C:\ZfServer\ and run the SETUP.EXE program to continue the update process as normal.
Status
This behaviour was corrected in the update as detailed in this technical note.
Last updated: 24 July 2003 (SV/DH)