Equisys technical notes

Technical guidance, explanations and fixes for our products

PRB: Brooktrout devices fail on server startup

Print

ZTN1522

ID: ZTN1522

This Zetafax technical note applies to:

  • Zetafax 2006 and later
  • Brooktrout TRxStream boards (TR1034 and Trufax BRI)

Symptom

After a server reboot faxes are no longer received. When viewing the Zetafax server monitor, all devices are in error and the log messages report:

SYSMAN     - (W) - Program BTBINIT not initialised correctly

Restarting the Zetafax server does not resolve the issue.

Cause

On server startup, the Zetafax service waits for the Brooktrout board configuration tool (CONFIGTOOL.EXE) to exit. As it does not do so in a timely fashion, Zetafax is unable to initialise the board.

Resolution

Use an updated version of BTBINIT.EXE to resolve the issue which is available for download from the following location:

btbinitv10.0.427.zip  

The update is specific to the type of board you have installed. If in doubt use the btbinit_pstn.exe version. If you receive an error on server restart that relates to the FOIP (Fax over IP) driver then use the btbinit_foip.exe version.

Follow the READ ME.TXT file instructions included in the package to apply the update.

Status

This has been identified by Equisys as a problem with the software versions given above.

Last updated: 30th May 2006 (GC/EB)

Keywords: red cross not idle btrout btb-g1

Equisys Logo, Document Management and Expense Management for Business Central
 

Replaced by script