FIX: Zetadocs Document Queue fails with "The length of the string must be less than or equal to 2048 characters" Print ZTN4576 This Zetadocs technical note applies to: Zetadocs Extension 3.0.22186 and earlier Symptom When navigating to the Zetadocs Document Queue, the error below is displayed and Zetadocs fails to load the list of documents. "The length of the string is xxxx, but it must be less than or equal to 2048 characters" Cause Zetadocs stores the barcode information in a table field limited to 2048 characters. When the cumulative length of the barcodes exceeds 2048 characters, the error occurs. Resolution This fault was corrected in an update, which is available in the Zetadocs Extension 3.0.22214.4 or later. Status This behaviour was corrected in the update detailed above. Last updated: 4th August 2022 (CR) Keywords: autolink string exceeded Update Related articles INFO: Changes in Brooktrout driver version 6.17.1 update FIX: Item tracking is no longer a requirement on journal items in Business Central with Zetadocs Extension installed FIX: Tables render incorrectly in PDF files when not using Native Rendering HOWTO: Upgrading the Zetadocs Expenses Connector for Business Central and NAV on-premises PRB: Unable to see document factbox when creating a new Document